* nscd/nscd.c (parse_opt): Read response from INVALIDATE request
to make sure the database has been already invalidated.
* nscd/cache.c (prune_cache): Add fd argument. Write response to fd
after the cache has been invalidated. Use pthread_mutex_lock rather
than pthread_mutex_trylock if fd != -1.
* nscd/connections.c (invalidate_cache): Add fd argument, write
response to fd if not calling prune_cache, pass fd to prune_cache.
(handle_request): Adjust invalidate_cache caller.
(nscd_run): Pass -1 as fd to prune_cache.
* nscd/cache.c (prune_cache): Take prunelock before starting the
work. Just return in case it is already taken.
(inet6_option_alloc): Now a simple wrapper around option_alloc.
* nscd/nscd_initgroups.c: Mark __gr_map_handle as hidden.
* nscd/nscd_getgr_r.c: Likewise.
* include/rpc/pmap_rmt.h: Mark all functions as hidden.
* nscd/nscd_getai.c (__hst_map_handle): Mark as hidden.
* nscd/nscd_gethst_r.c (__hst_map_handle): Likewise.
* stdlib/longlong.h (__clz_tab): Mark as hidden.
* iconv/gconv_int.h: Mark __gconv_lock as hidden.
2006-05-02 Ulrich Drepper <drepper@redhat.com>
[BZ #2632]
* nscd/connections.c (nscd_init): Correct initialization of
in-memory database structure.
* iconvdata/utf-7.c: Don't require more than one character after
* nscd/nscd_conf.c (nscd_parse_file): Parse auto-propagate lines.
* nscd/nscd.conf: Add auto-propagate lines.
* nscd/connections.c (dbs): Initialize .propagate fields.
* nscd/grpcache.c (cache_addgr): Do not add ID entry for name lookups
and vice versa if propagation is disabled for the database.
* nscd/pwdcache.c (cache_addpw): Likewise.
* nscd/nscd_helper.c (__nscd_get_map_ref): Make mapptr argument a
volatile pointer so that the mapptr->mapped value is re-read after
the lock is retrieved.
* nscd/nscd-client.h: Update __nscd_get_map_ref prototype.
* sysdeps/unix/sysv/linux/ia64/clone2.S: Check for NULL stack
invalid length [Coverity CID 106].
* nss/nss_files/files-key.c (search): Close stream before
successful return [Coverity CID 107].
* io/fts.c (fts_open): Don't allocate parent if *argv==NULL
[Coverity CID 108].
* sunrpc/rpc_cout.c (inline_struct): Free sizestr after use
[Coverity CID 110, 109].
* sunrpc/rpc_scan.c (docppline): Free file string if it is not
going to be used [Coverity CID 111].
* sysdeps/unix/sysv/linux/getsourcefilter.c (getsourcefilter): Free
memory if socket level value cannot be retrieved [Coverity CID 112].
* nis/nis_clone_dir.c (nis_clone_directory): Free all memory in
error case [Coverity CID 114].
* nis/nis_clone_res.c (nis_clone_result): Free all memory in the
error cases [Coverity CID 115].
* sunrpc/rpc_parse.c (get_definition): Free defp if tok ==
TOK_EOF [Coverity CID 116].
* sysdeps/unix/sysv/linux/setsourcefilter.c (setsourcefilter): Free
memory if socket level value cannot be retrieved [Coverity CID 117].
* elf/cache.c (save_cache): Initialize pad to avoid writing
uninitialized data to disk.
* elf/cache.c (save_cache): Free file_entries_new [Coverity CID 118].
* intl/finddomain.c (_nl_find_domain): Avoid strdup of expand
locale name, use strdupa. Remove free call [Coverity CID 119].
* sunrpc/rpc_main.c (generate_guard): Avoid extra allocation and
the resulting leak [Coverity CID 121].
* sunrpc/rpc_main.c (mkfile_output): Free all allocated memory
[Coverity CID 122].
* sunrpc/rpc_main.c (h_output): Free guard after we are done
[Coverity CID 123].
* sunrpc/svc_udp.c (cache_set): Free victim if newbuf allocation
fails [Coverity CID 126].
* sunrpc/svc_udp.c (svcudp_enablecache): Free memory in error
cases [Coverity CID 127].
* nis/nis_table.c (__create_ib_request): Free ibreq in case strdup
fails [Coverity CID 128].
* nis/nis_getservlist.c (nis_getservlist): Free all memory in case
of an error [Coverity CID 130, 129].
* nis/nis_print_group_entry.c (nis_print_group_entry): If
nis_lookup call failed, return. Free lookup result in error
cases [Coverity CID 131].
* nis/nis_removemember.c (nis_removemember): Free all memory in
error cases [Coverity CID 132].
* nis/nss_nisplus/nisplus-alias.c (_nss_nisplus_getaliasbyname_r):
Always free lookup result [Coverity CID 134].
* nis/nss_nisplus/nisplus-ethers.c (_nss_nisplus_gethostton_r):
Always free lookup result [Coverity CID 135].
* nis/nss_nisplus/nisplus-ethers.c (_nss_nisplus_getntohost_r):
Always free lookup result [Coverity CID 136].
* nis/nss_nisplus/nisplus-network.c (_nss_nisplus_getnetbyaddr_r):
Before retrying, free old result [Coverity CID 137].
* nis/nss_nisplus/nisplus-publickey.c (_nss_nisplus_netname2user):
Free res in case UID is zero [Coverity CID 138].
* nis/ypclnt.c (yp_update): Always free master string
[Coverity CID 140].
* nis/nis_creategroup.c (nis_creategroup): Free all memory in
error cases [Coverity CID 143, 142, 141].
* nis/nss_nis/nis-publickey.c (_nss_nis_getpublickey): Free result
if yp_match call succeeded [Coverity CID 155].
* nis/nss_nis/nis-publickey.c (_nss_nis_getsecretkey): Free string
allocated in yp_match at all times [Coverity CID 157, 156].
* nscd/nscd.c (write_pid): Close stream also if writing failed
[Coverity CID 165].
* nis/nis_table.c (nis_add_entry): Move test for NULL parameter
ahead of first use [Coverity CID 167].
* nis/nss_nis/nis-alias.c (_nss_nis_getaliasbyname_r): Move test
for NULL parameter ahead of first use [Coverity CID 168].
* intl/finddomain.c (_nl_find_domain): We never return NULL if we
found the locale [Coverity CID 169].
* inet/getnameinfo.c (getnameinfo): __getservbyport_r does not set
herrno [Coverity CID 178].
* nis/nis_checkpoint.c (nis_checkpoint): Don't access and returned
freed object [Coverity CID 182].
2006-04-01 Ulrich Drepper <drepper@redhat.com>
[BZ #2498]
* nscd/connections.c (main_loop_poll): If the connection cannot be
accepted because of user-imposed limits close the descriptor.
* ncsd/aicache.c: Don't use sendfile for records on the stack.
* nscd/grpcache.c: Likewise.
* nscd/hstcache.c: Likewise.
* nscd/initgrcache.c: Likewise.
* nscd/pwdcache.c: Likewise.
Patch by dmueller@suse.com.
(struct shmid_ds): Use it for shm_nattch field.
2005-11-18 Jakub Jelinek <jakub@redhat.com>
* sysdeps/unix/sysv/linux/futimesat.c (futimesat): If FILE is NULL,
set access and modification times of the file referenced by FD.
* sysdeps/generic/futimesat.c (futimesat): Don't return EINVAL if
FILE is NULL. Don't check FD if FILE is absolute path.
2005-11-19 Ulrich Drepper <drepper@redhat.com>
* nscd/nscd_gethst_r.c (nscd_gethst_r): Avoid unnecesary read call
if there are no aliases.
* sysdeps/unix/sysv/linux/Makefile (CFLAGS-connections.c,
CFLAGS-pwdcache.c, CFLAGS-grpcache.c, CFLAGS-hstcache.c,
CFLAGS-aicache.c, CFLAGS-initgrcache.c): Add -DHAVE_SENDFILE.
* sysdeps/unix/sysv/linux/kernel-features.h (__ASSUME_SENDFILE):
Define.
* nscd/pwdcache.c [HAVE_SENDFILE]: Include <sys/sendfile.h> and
<kernel-features.h>.
[HAVE_SENDFILE] (cache_addpw): Use sendfile to transmit positive
result.
* nscd/grpcache.c: Likewise.
* nscd/hstcache.c: Likewise.
* nscd/aicache.c: Likewise.
* nscd/initgrcache.c: Likewise.
* nscd/connectionc.c: Likewise.
(dbs): Initialize max_db_size fields.
(nscd_init): When mapping the database, use max_db_size as the
mapping size even if it is bigger than the file size.
* nscd/mem.c (mempool_alloc): When resizing the file make sure the
limit in max_db_size is not exceeded. Don't use mremap, just
posix_fallocate is enough (according to Linus). Use posix_fallocate
correctly.
* nscd/nscd.conf: Add max-db-size parameters.
* nscd/nscd.h (struct database_dyn): Add max_db_size field.
Define DEFAULT_MAX_DB_SIZE and DEFAULT_DATASIZE_PER_BUCKET.
Temporarily define TEMP_FAILURE_RETRY_VAL here.
* nscd/nscd_conf.c (nscd_parse_file): Parse max-db-size parameter
and add sanity checks for it.
* nscd/aicache.c (addhstaiX): Use send with MSG_NOSIGNAL not write to
send reply.
* nscd/connection.c (writeall): Likewise.
(handle_request): Likewise.
* nscd/grpcache.c (cache_addgr): Likewise.
* nscd/hstcache.c (cache_addhst): Likewise.
* nscd/initgrcache.c (addinitgroupsX): Likewise.
* nscd/nscd.c (parse_opt): Likewise.
* nscd/nscd_stat.c (send_stats): Likewise.
(receive_print_stats): Likewise.
* nscd/pwdcache.c (cache_addpw): Likewise.