A few math functions still use __fabs(f/l) rather than fabs, which
means they won't be inlined. Rename them so they are inlined.
Also add -fno-builtin-fabsl to nofpu powerpc makefile to work around
BZ #29253.
* sysdeps/ieee754/dbl-64/e_lgamma_r.c
(__ieee754_lgamma_r): Use fabs rather than __fabs.
* sysdeps/ieee754/dbl-64/e_log10.c (__ieee754_log10): Likewise.
* sysdeps/ieee754/dbl-64/e_log2.c (__ieee754_log2): Likewise.
* sysdeps/ieee754/flt-32/e_lgammaf_r.c
(__ieee754_lgammaf_r): Use fabsf rather than __fabsf.
* sysdeps/ieee754/flt-32/e_log10f.c (__ieee754_log10f): Likewise.
* sysdeps/ieee754/flt-32/e_log2f.c (__ieee754_log2f): Likewise.
* sysdeps/ieee754/ldbl-128/e_lgammal_r.c
(__ieee754_lgammal_r): Use fabsl rather than __fabsl.
* sysdeps/ieee754/ldbl-128/e_log10l.c (__ieee754_log10l): Likewise.
* sysdeps/ieee754/ldbl-128/e_log2l.c (__ieee754_log2l): Likewise.
* sysdeps/ieee754/ldbl-128ibm/e_lgammal_r.c
(__ieee754_lgammal_r): Use fabsl rather than __fabsl.
* sysdeps/ieee754/ldbl-128ibm/e_log10l.c (__ieee754_log10l): Likewise.
* sysdeps/ieee754/ldbl-128ibm/e_log2l.c (__ieee754_log2l): Likewise.
* sysdeps/powerpc/nofpu/Makefile: Add -fno-builtin-fabsl for BZ #29253.
This runs the attached sed script against these files using
a regex which aggressively matches long double literals
when not obviously part of a comment.
Likewise, 5 digit or less integral constants are replaced
with integer constants, excepting the two cases of 0 used
in large tables, which are also the only integral values
of the form x.0*E0L encountered within these converted
files.
Likewise, -L(x) is transformed into L(-x).
Naturally, the script has a few minor hiccups which are
more clearly remedied via the attached fixup patch. Such
hiccups include, context-sensitive promotion to a real
type, and munging constants inside harder to detect
comment blocks.
Add a layer of macro indirection for long double files
which need to be built using another typename. Likewise,
add the L(num) macro used in a later patch to override
real constants.
These macros are only defined through the ldbl-128
math_ldbl.h header, thereby implicitly restricting
these macros to machines which back long double
with an IEEE binary128 format.
Likewise, appropriate changes are made for the few
files which indirectly include such ldbl-128 files.
These changes produce identical binaries for s390x,
aarch64, and ppc64.
As with various other issues of this kind, bug 16977 is log10 (1)
wrongly returning -0 rather than +0 in round-downward mode because of
an implementation effectively in terms of log1p (x - 1). This patch
fixes the issue in the same way used for log.
Tested x86_64 and x86 and ulps updated accordingly. Also tested for
mips64 to confirm a fix was needed for ldbl-128 and to validate that
fix (also applied to ldbl-128ibm since that version of logl is
essentially the same as the ldbl-128 one).
[BZ #16977]
* sysdeps/i386/fpu/e_log10.S (__ieee754_log10): Take absolute
value when x - 1 is zero.
* sysdeps/i386/fpu/e_log10f.S (__ieee754_log10f): Likewise.
* sysdeps/i386/fpu/e_log10l.S (__ieee754_log10l): Likewise.
* sysdeps/ieee754/ldbl-128/e_log10l.c (__ieee754_log10l): Return
0.0L for an argument of 1.0L.
* sysdeps/ieee754/ldbl-128ibm/e_log10l.c (__ieee754_log10l):
Likewise.
* sysdeps/x86_64/fpu/e_log10l.S (__ieee754_log10l): Take absolute
value when x - 1 is zero.
* math/libm-test.inc (log10_test): Use ALL_RM_TEST.
* sysdeps/i386/fpu/libm-test-ulps: Update.
* sysdeps/x86_64/fpu/libm-test-ulps: Likewise.
2001-11-10 Andreas Jaeger <aj@suse.de>
* sysdeps/ieee754/ldbl-128/e_log2l.c: New file.
* sysdeps/ieee754/ldbl-128/e_log10l.c: Likewise.
Contributed by Stephen L Moshier <moshier@mediaone.net>.