Pixdata is deprecated but some software already use GtkImage widgets
with image data loaded from GResource-backed pixdata. As the
security-problem ridden pixdata loader was removed, we need to manually
check whether the GResource data is pixdata, and load it manually.
https://bugzilla.gnome.org/show_bug.cgi?id=781583
Use the new predictable request object path and connect
to the Response signal before issuing the portal call.
This avoids a race that is pretty unlikely to hit in
the filechooser case.
Wacom tablets often have a "pad" device which houses multiple buttons. At
present, these devices are incorrectly marked as GDK_SOURCE_PEN which can
cause problems for some software.
https://bugzilla.gnome.org/show_bug.cgi?id=782040
By relying on GtkSpinButton default activation behavior, the
collate icon doesn't get updated when a new number is typed
in the copies spin button.
https://bugzilla.gnome.org/show_bug.cgi?id=759308
It was only testing the default configuration, where overlay scrolling
is on and both scrollbars use POLICY_AUTOMATIC. We should also test the
other 3 configurations that are available by including non-overlay
scrollbars and/or those that use POLICY_ALWAYS.
https://bugzilla.gnome.org/show_bug.cgi?id=778853
POLICY_AUTOMATIC means scrollbars are only shown when needed, i.e. when
the size of the window is not large enough to show the entire child. So
when measuring the preferred size, such scrollbars should be ignored.
But measure() added size for *any* non-overlay scrollbar of the opposite
orientation, e.g. for horizontal size, it added the width of vscrollbar.
So we requested for child + bar, & having enough for child meant that the
policy hid the bar, leaving extra space empty below/right of the child.
Fix this by only adding size for such bars if they use POLICY_ALWAYS.
https://bugzilla.gnome.org/show_bug.cgi?id=778853
Under Wayland, when multiple keys are pressed and the user releases a
key, key repeat should continue unless the key released is the one
currently repeating.
In the case of:
- key1 press
- key1 repeat
- key2 press -> key1 repeat stopped
- key2 repeat
- key2 release
The behavior should be to cancel keyboard repeat, though key1 is still
held down. This is consistent with prior X11/XWayland behavior.
The following also must work:
- key1 press
- key2 press
- key2 release
- key2 press
- key1 release
- key2 should continue to repeat
The fix for bug #778019 should continue to work:
- key1 press
- key1 repeat
- key2 press -> key1 repeat stopped
- key1 release
- key2 should repeat
The choice to change the counter nkeys to the flag repeat_active
helps to solve the second test case.
https://bugzilla.gnome.org/show_bug.cgi?id=781285
begin_resize_drag() and begin_move_drag() check for xdg_surface being
not null, but those apply on xdg_toplevel so they should check for
xdg_toplevel being non-null instead.
https://bugzilla.gnome.org/show_bug.cgi?id=781945
When an event is received while a tooltip is showing, the GtkTooltip's
event handling code can end up calling gdk_window_set_transient_for()
from gtk_tooltip_set_last_window().
The Wayland GDK backend will try to automatically create a subsurface
in gdk_wayland_window_set_transient_for() but if the parent surface is
gone meanwhile, this will will cause a crash when trying to create a
subsurface from a parent with a null surface.
Checking for the parent is not sufficient, we ought to check for the
parent surface as well to avoid the crash.
https://bugzilla.gnome.org/show_bug.cgi?id=782283