The restored test data was marked as failing, but appears to pass, and
the available history does not explain why it was commented out.
Change-Id: I7e9e3ba72fc8fef42c91ee882efa98d25b3d8317
Reviewed-by: Rohan McGovern <rohan.mcgovern@nokia.com>
When using QSignalSpy, always verify that the signal spy is valid. This
will cause the test to give a meaningful failure when spying on a
non-existant signal. Without this change, tests that spy on a signal to
ensure that it is not emitted (i.e. by comparing the spy count to zero)
could pass erroneously if something went wrong when creating the signal
spy, as an invalid QSignalSpy will always return a count of zero.
Change-Id: I41f4a63d9f0de9190a86de237662dc96be802446
Reviewed-by: Thiago Macieira <thiago.macieira@intel.com>
Reviewed-by: Rohan McGovern <rohan.mcgovern@nokia.com>