qt5base-lts/tests
Morten Johan Sørvig 00f2d1a09b Establish baseline for QIcon test on dpr > 1
After enabling Qt::AA_UseHighDpiPixmaps, QIcon::pixmap()
now returns pixmaps larger than the requested size on
devicePixelRatio > 1 screens.

Adapt tests to account for this changed behavior.
Skip tests where it’s unclear what the the expected
behavior is, or where the test logic does not apply
to dpr > 1.

This gives a clearer indication of where we are
(39 passed, 0 failed, 9 skipped), and enables using
the qicon test to catch regressions also when running
at dpr > 1.

Remove the "lowdpi" testcase flags from the qmake and
cmake project files.

Change-Id: Ia7ce722ae356fc496a91b54e9f5d590d13b9df62
Reviewed-by: Tor Arne Vestbø <tor.arne.vestbo@qt.io>
2020-08-05 11:23:07 +02:00
..
auto Establish baseline for QIcon test on dpr > 1 2020-08-05 11:23:07 +02:00
baselineserver Use QList instead of QVector in benchmarks tests 2020-06-25 10:13:31 +02:00
benchmarks Privately introducing QDecompressHelper for network purposes 2020-08-05 09:17:11 +02:00
global
libfuzzer Add ; to Q_UNUSED 2020-07-07 11:51:48 +02:00
manual Remove last remaining bits of QtPlatformHeaders 2020-08-04 07:12:32 +02:00
shared Remove winrt 2020-06-06 20:25:49 +02:00
testserver Fix perl script warning 2020-03-19 14:15:04 +00:00
.prev_CMakeLists.txt Make standalone tests build via top level repo project 2019-11-08 15:42:32 +00:00
CMakeLists.txt CMake: Handle finding of OpenSSL headers correctly 2020-04-08 22:03:24 +02:00
README
tests.pro

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.