Giuseppe D'Angelo 07d80deeab QtWidgets: restore Qt 5 compatibility for save/restore state
Several classes in QWidget use QDataStream internally in order
to save and restore state. These QDataStream usages were not
versioned, meaning that if Qt changes the serialization for some
datatype, then the data saved between different Qt versions becomes
incompatible. Note that the save/restore API in question just produce
opaque blobs as QByteArrays -- the user has no control over the
QDataStream objects and thus versions.

Fix by version the usages.

In QHeaderView this has caused a regression because QBitArray *did*
change version between Qt 5 and 6. In general, using QDataStream without
explicit versioning is a mistake, so deploy the same fix elsewhere as
well.

Fixes: QTBUG-99487
Pick-to: 5.15 6.2 6.3
Change-Id: I82bb5c266f4e5dedc0887cbef855dccab1015e29
Reviewed-by: Volker Hilsheimer <volker.hilsheimer@qt.io>
Reviewed-by: <doctor.whom@gmail.com>
2022-05-18 02:21:31 +02:00
..
auto QtWidgets: restore Qt 5 compatibility for save/restore state 2022-05-18 02:21:31 +02:00
baseline Stylesheet: fix toolbutton menu indicator rendering 2022-05-16 20:32:27 +02:00
benchmarks QTextDocument/QGraphicsTextItem: skip layout in setTextWidth(0) 2022-05-17 22:37:40 +02:00
global
libfuzzer Use SPDX license identifiers 2022-05-16 16:37:38 +02:00
manual Use SPDX license identifiers 2022-05-16 16:37:38 +02:00
shared Use SPDX license identifiers 2022-05-16 16:37:38 +02:00
testserver Use SPDX license identifiers 2022-05-16 16:37:38 +02:00
CMakeLists.txt
README

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.