qt5base-lts/tests
Jan Arve Saether 0efc6e92d8 Use the default height (not 0) if only width is specified
If width was specified, but not height (or vice versa) the actual
window size was not as expected:
* The window width was not the width specified.
* The window height became 0.
This was unexpected, since if both width and height was not specified
it would fallback to becoming 160x160 (on Windows).

However, with the advent of https://codereview.qt-project.org/71999
both width and height might receive sensible defaults based on the
content of the ApplicationWindow, which would mean that it might be
reasonable to expect that you only need to specify one size component
of the window.

This also fixes an assertion in file
..\..\..\3rdparty\angle\src\libGLESv2\renderer\SwapChain9.cpp, line 81
The assertion happened when a window was created with 0 height (but
valid width), and then its height got increased, causing it to become
visible.

Change-Id: Ia9e730418e35d679907bdcc59b00c3c988216c32
Reviewed-by: Shawn Rutledge <shawn.rutledge@digia.com>
2014-01-09 19:27:32 +01:00
..
auto Use the default height (not 0) if only width is specified 2014-01-09 19:27:32 +01:00
baselineserver WinRT: Fix various test compilations 2013-10-02 12:36:05 +02:00
benchmarks WinRT: Fixed compilation of network autotests and benchmarks 2013-12-06 15:06:47 +01:00
global tst_bic: Add linux-gcc-ia32 bic data for QtXml 2013-01-16 08:25:28 +01:00
manual Merge remote-tracking branch 'origin/stable' into dev 2013-12-16 16:59:33 +01:00
shared WinRT: Fix various test compilations 2013-10-02 12:36:05 +02:00
README Doc: Fix references to Qt Test 2013-01-30 01:35:06 +01:00
tests.pro Properly implement a 'make docs' target for subdirs and apps/libs 2012-05-09 08:34:42 +02:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.