Volker Hilsheimer 1ce3585305 Detect double timer during single timeout in registerTimer test, and skip
We observe this happening on macOS in the CI system, and it might happen
if a VM doesn't get CPU cycles for long enough time so that two timers
time out. Then event processing will process two timer events, and we
overwrite the timerIdFromEvent with the second event.

Instead, skip the test when this happens.

This is an ammendment to 5c520f4b0a

Fixes: QTBUG-71751
Reviewed-by: Timur Pocheptsov <timur.pocheptsov@qt.io>
Reviewed-by: Tor Arne Vestbø <tor.arne.vestbo@qt.io>
(cherry picked from commit 67491e2df5)
Change-Id: I30eef8cfc94988e6cad500dd5e6722488c2985be
2020-02-22 02:52:36 +01:00
..
auto Detect double timer during single timeout in registerTimer test, and skip 2020-02-22 02:52:36 +01:00
baselineserver Merge remote-tracking branch 'origin/5.13' into 5.14 2019-09-09 07:51:49 +00:00
benchmarks Skip instead of fail tests when test server is not available 2020-01-14 00:15:16 +01:00
global tst_bic: Add linux-gcc-ia32 bic data for QtXml 2013-01-16 08:25:28 +01:00
libfuzzer Fuzzing: Update location of testcases in Readme 2019-11-21 13:41:18 +01:00
manual Pass QDate and QTime by value in manual calendar test code 2020-01-31 14:02:53 +01:00
shared Remove usages of Q_OS_WINCE 2019-05-23 13:51:05 +02:00
testserver docker-compose now brings up the docker images tagged as "latest" 2019-12-05 15:40:00 +01:00
README Doc: Fix references to Qt Test 2013-01-30 01:35:06 +01:00
tests.pro Build examples and tests only if their requirements are met 2017-03-22 15:55:55 +00:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.