Sometimes this test would fail due to the session not actually being reused. The cause of this was that the requests were sometimes being completed 1-by-1, enabling the individual requests to re-use the already-connected socket completely because it stayed connected. Setting the Connection-header to close lets us be sure that the socket cannot be re-used when the request is finished. Fixes: QTBUG-82846 Change-Id: I5da8baa50a3a45fb60f1e1613e500e3e9c034fb0 Reviewed-by: Timur Pocheptsov <timur.pocheptsov@qt.io> |
||
---|---|---|
.. | ||
auto | ||
baselineserver | ||
benchmarks | ||
global | ||
libfuzzer | ||
manual | ||
shared | ||
testserver | ||
README | ||
tests.pro |
This directory contains autotests and benchmarks based on Qt Test. In order to run the autotests reliably, you need to configure a desktop to match the test environment that these tests are written for. Linux X11: * The user must be logged in to an active desktop; you can't run the autotests without a valid DISPLAY that allows X11 connections. * The tests are run against a KDE3 or KDE4 desktop. * Window manager uses "click to focus", and not "focus follows mouse". Many tests move the mouse cursor around and expect this to not affect focus and activation. * Disable "click to activate", i.e., when a window is opened, the window manager should automatically activate it (give it input focus) and not wait for the user to click the window.