Mårten Nordheim 5a235da270 tst_QTcpSocket: fix disconnectWhileLookingUp
... and unblacklist it on Windows.

From what I can tell there is no particular reason why this test fails
other than that it is a little too slow sometimes (these things happen).

So, to fix the test I bumped the timeout, but to avoid the test running
for longer on every test-run it now also ends when the socket enters
the "Unconnected" state.

Previously it failed 171/500 times, and after this patch it failed
0/1000 times.

Change-Id: I4266bff6b91aaaf502ee66265d01c3a177706402
Reviewed-by: Edward Welbourne <edward.welbourne@qt.io>
Reviewed-by: Thiago Macieira <thiago.macieira@intel.com>
Reviewed-by: Jesus Fernandez <Jesus.Fernandez@qt.io>
2017-11-24 04:54:58 +00:00
..
auto tst_QTcpSocket: fix disconnectWhileLookingUp 2017-11-24 04:54:58 +00:00
baselineserver tests: Add Q_FALLTHROUGH to unmarked fallthroughs seen by GCC 7 2017-06-28 17:57:35 +00:00
benchmarks Restore compatibility with pre-5.9 Keccak calculation 2017-09-21 03:21:58 +00:00
global tst_bic: Add linux-gcc-ia32 bic data for QtXml 2013-01-16 08:25:28 +01:00
manual Menurama: Fix custom application class constructor signature 2017-11-17 13:30:40 +00:00
shared Fix largefile tests on ARM and QEMU targets 2017-03-28 06:55:32 +00:00
README Doc: Fix references to Qt Test 2013-01-30 01:35:06 +01:00
tests.pro Build examples and tests only if their requirements are met 2017-03-22 15:55:55 +00:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.