qt5base-lts/tests
M. Moellney 705d29585b Fix qSetMessagePattern to have many time/backtrace parts
The previous implementation overwrote multiple 'time' parts in the
qSetMessagePattern with the last setting in the pattern line.
%{time}%{time process}%{time boot} ended up to be output as if
%{time boot}%{time boot}%{time boot} was set.

This fix keeps the arguments of each individual 'time' part.

The same holds for multiple 'backtrace' parts. The previouse
implementation overwrote multiple 'backtrace' arguments with the
arguments of the last occurrence.

This fix keeps the individual arguments for the 'process' parts.

The individual arguments are applied in qFormatLogMessage.

A new test to verify the individual 'time' arguments application
is added, too.

Task-number: QTBUG-51944
Change-Id: Ib757614a482c5f31ed0a61b550daa2eea4b907b4
Reviewed-by: Olivier Goffart (Woboq GmbH) <ogoffart@woboq.com>
2016-03-25 11:03:43 +00:00
..
auto Fix qSetMessagePattern to have many time/backtrace parts 2016-03-25 11:03:43 +00:00
baselineserver Update copyright headers 2015-02-11 06:49:51 +00:00
benchmarks Remove temporary string allocations when reading prepared statement. 2015-08-13 16:53:45 +00:00
global tst_bic: Add linux-gcc-ia32 bic data for QtXml 2013-01-16 08:25:28 +01:00
manual Manual High DPI test: Create Dnd pixmap with device pixel ratio. 2016-03-16 14:40:15 +00:00
shared Update copyright headers 2015-02-11 06:49:51 +00:00
README Doc: Fix references to Qt Test 2013-01-30 01:35:06 +01:00
tests.pro iOS: Enable building of basic tests 2014-01-22 12:35:17 +01:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.