qt5base-lts/tests
Alex Trotsenko 6adff20fe6 Fix bytesAvailable() on UDP under Windows
When ::WSAIoctl() reports 1 byte available for reading, we are trying
to peek an incoming datagram to ensure that the data is actually
delivered. But, according to MSDN docs, we are not allowed to pass NULL
as 'lpNumberOfBytesRecvd' parameter to ::WSARecvFrom() call, if
'lpOverlapped' parameter is also NULL.

The case with an empty datagram is fixed accordingly.

Change-Id: Id13038245332d3fb4bc18038d44a7cfd7ce04775
Reviewed-by: Edward Welbourne <edward.welbourne@qt.io>
Reviewed-by: Thiago Macieira <thiago.macieira@intel.com>
2017-07-30 13:02:30 +00:00
..
auto Fix bytesAvailable() on UDP under Windows 2017-07-30 13:02:30 +00:00
baselineserver tests: Add Q_FALLTHROUGH to unmarked fallthroughs seen by GCC 7 2017-06-28 17:57:35 +00:00
benchmarks Deprecate QCoreApplication::flush() 2017-04-22 15:18:01 +00:00
global tst_bic: Add linux-gcc-ia32 bic data for QtXml 2013-01-16 08:25:28 +01:00
manual qtabbar manual test: Improve usability 2017-07-06 00:58:17 +00:00
shared Fix largefile tests on ARM and QEMU targets 2017-03-28 06:55:32 +00:00
README Doc: Fix references to Qt Test 2013-01-30 01:35:06 +01:00
tests.pro Build examples and tests only if their requirements are met 2017-03-22 15:55:55 +00:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.