qt5base-lts/tests
Mårten Nordheim 2253d5eca6 Schannel: Properly handle request for certificate
Certain servers, like smtp.live.com, will send a request for a
certificate even though they don't require one. In Schannel this
manifests as a warning/info status (SEC_I_INCOMPLETE_CREDENTIALS).
In the cases where it's not needed we should suppress the warning and
try to connect anyway, which is done by calling
InitializeSecurityContext again when we get the status.

Pick-to: 5.15
Change-Id: I3c48140f2949d8557251a49a2b66946da9395736
Reviewed-by: Joshua GPBeta <studiocghibli@gmail.com>
Reviewed-by: Timur Pocheptsov <timur.pocheptsov@qt.io>
2020-09-14 17:14:00 +02:00
..
auto Schannel: Properly handle request for certificate 2020-09-14 17:14:00 +02:00
baselineserver Use QList instead of QVector in benchmarks tests 2020-06-25 10:13:31 +02:00
benchmarks QStyleOptionGraphicsItem: remove deprecated member matrix/levelOfDetail 2020-09-06 18:31:43 +02:00
global
libfuzzer Add ; to Q_UNUSED 2020-07-07 11:51:48 +02:00
manual QNAM: Enable HTTP/2 by default 2020-09-10 18:28:43 +02:00
shared Use C++17 [[maybe_unused]] 2020-09-06 18:31:43 +02:00
testserver Fix perl script warning 2020-03-19 14:15:04 +00:00
.prev_CMakeLists.txt Make standalone tests build via top level repo project 2019-11-08 15:42:32 +00:00
CMakeLists.txt CMake: Properly handle CONFIG += thread aka Threads::Threads 2020-08-06 19:15:39 +02:00
README
tests.pro Build examples and tests only if their requirements are met 2017-03-22 15:55:55 +00:00

This directory contains autotests and benchmarks based on Qt Test. In order
to run the autotests reliably, you need to configure a desktop to match the
test environment that these tests are written for.

Linux X11:

   * The user must be logged in to an active desktop; you can't run the
     autotests without a valid DISPLAY that allows X11 connections.

   * The tests are run against a KDE3 or KDE4 desktop.

   * Window manager uses "click to focus", and not "focus follows mouse". Many
     tests move the mouse cursor around and expect this to not affect focus
     and activation.

   * Disable "click to activate", i.e., when a window is opened, the window
     manager should automatically activate it (give it input focus) and not
     wait for the user to click the window.